ARCHSPLACE
Architecture, made simple — since 2018
Soil pipe

PlanHSin the studio

Soil pipe

Soil pipe places the vertical pipe down which the waste water falls, with one click where it stands. Every waste point of a level then drains to the nearest soil pipe, through a network the studio lays on its own.

What it is

A soil pipe is the vertical pipe that carries waste water down through the building. Its tool places one with a single click, at the point where it stands; the pipe then runs vertically through every level, from below its lowest branch to 40 cm above the roof covering where it passes through, and that is its vent. Its panel can stop it in the attic on an air admittance valve instead.

The soil pipe is where the drainage goes. The waste points of every level drain to their nearest soil pipe, in one network the studio lays on its own, with its slope, its diameters and its fittings. None of the network is stored: add a soil pipe, or move one, and the network is laid again.

When to use it

  • To start the drainage of a house: place one soil pipe near the toilets and the kitchen.
  • To add a second soil pipe so that a distant toilet drains into its own.
  • To choose between a vent through the roof and an air admittance valve.

The steps

  1. Pick the tool. Type H and then S quickly, or pick it on the toolbar, where it shares one button with the other plumbing tools. The status bar tells you that every appliance drains to the nearest soil pipe.

    Pick the tool. Type H and then S quickly, or pick it on the toolbar, where it shares one button with the other plumbing tools.
  2. Click where it stands. The magnet holds the click on the nearest point within reach, such as the corner of a wall. The soil pipe is placed there and runs through every level. Every click places one more soil pipe.

    Click where it stands. The magnet holds the click on the nearest point within reach, such as the corner of a wall.
  3. Set its vent in its panel. Select the soil pipe with Select. Its Vent field reads Through the roof, or Air admittance valve in the attic.

    Set its vent in its panel. Select the soil pipe with Select.

What it refuses

  • Nothing at the click. A soil pipe is placed wherever you click. The project then says on its panel when it stands in a column, a beam or an opening, and over what length.

What it writes to the contract

One new entry at the end of the project's list of risers, as one step that one undo reverses: its position in metres, the soil and waste system it carries, and the phase in which the view draws. It names no level, since it runs through all of them. The vent is written only when you choose the valve. The drains and their fittings are never written.

Concepts

Common questions

Into which soil pipe does a wash basin drain?

Into the nearest one. The waste points of every level drain to their nearest soil pipe, as one network with its slope and its fittings, laid by the studio.

How is the soil pipe vented?

By default it rises 40 cm above the roof covering where it passes through it. In its panel, the Vent field can stop it in the attic on an air admittance valve instead.