PlanHin the studio
Plumbing point
Plumbing places a water supply point or a waste point with one click, on a wall or in the floor of a room. The pipes are not drawn by hand: the supply from the manifold or the water meter, and the drainage to the nearest soil pipe, are laid on their own.
What it is
The Plumbing tool places the points of the plumbing: where water comes in and where it goes out. The list beside the tools offers the points of your template; in a project under BIS, the Indian practice, for example: cold and hot water points, a stop cock, a distribution manifold, a WC soil outlet, wastes for a wash basin, a bidet, a kitchen sink, a bath, a washing machine and a dishwasher, a shower floor trap, waste drains of 40 and 50 mm, a soil drain of 110 mm, a floor trap (nahani), a vent pipe and a rainwater pipe. The water meter has a tool of its own.
The pipes follow on their own. The supply is laid as a star: every cold and hot water point gets its own run from the nearest manifold, or from the water meter when there is none, through the floor and up its wall. The waste points of every level drain to the nearest soil pipe, in one network laid with its slope and fittings. None of this is stored: move a point and the pipes are laid again. They show with the Plumbing overlay.
When to use it
- To place the supply and waste points of a toilet, a kitchen or a wash area.
- To add a floor trap to a shower or a car parking.
- To check the network the studio lays as you add points.
The steps
Pick the tool. Press
H, or click the Plumbing button. The status bar asks you to click a wall or inside a room.
Choose the point. Pick it from the list beside the tools.

Click where it stands. A supply point, a stop cock or a manifold stands on a wall: click on the wall or within about 60 cm of it, on the side it faces. A floor trap stands in a room: click inside the room. A waste point goes where you click: within about 45 cm of a wall it stands on that wall, farther away it stands in the floor of the room you clicked in.

Adjust it in its panel. Select the point with Select to set its mounting height, and to read what its pipes could not do, if anything.

What it refuses
- A wall point far from every wall. Farther than about 60 cm from any wall, nothing is placed.
- A floor point outside a room. Outside every room enclosed by walls, a message asks you to click inside a room, and nothing is placed.
- The same point twice. A point of the same kind on the same face of the same wall, within 5 cm of one already there, is refused with a message: place it beside the existing one.
- A point that no pipe can reach. The project flags a point set in an opening or over a hole in the floor, and says on its panel when its pipe had to cross a hole, a column, a beam or an opening.
What it writes to the contract
One new entry at the end of the project's list of points, as one step that one undo reverses: its kind, and either its wall, its distance along it and its face, or its room and its position in the floor, along with the phase in which the view draws. The pipes, their diameters, slopes and fittings are never written: they are worked out from the points every time the project is built.
Concepts
Common questions
Is placing a WC enough to get its drainage?
No. A sanitary appliance is architecture and connects to nothing. The plumbing starts at its points: place the WC soil outlet, and its cold water point, with this tool.
Where does the drainage go?
The waste points of every level drain to their nearest soil pipe, laid as one network with its slope and fittings. Place at least one soil pipe with the Soil pipe tool.
Does a waste point go in the wall or in the floor?
It goes where you click: within about 45 cm of a wall it stands on that wall, farther away it stands in the floor of the room.